pv_SetAcceleration()

描述

Set the profile acceleration object.

Relevant Objects

  • Object 6083h: Profile acceleration

語法

int pv_SetAcceleration(uint32_t value);

參數

  • [in] value

The profile acceleration to be set.

回傳值

Return an error code. If the returned value is zero, it indicates a successful execution of this function.

備註

This function must be called after a successful execution of EthercatMaster::begin(). This function is non-blocking and can be called in callback functions if the related object is mapped to PDO.

範例程式碼

#include "Ethercat.h" 

EthercatMaster master; 
EthercatDevice_CiA402 motor; 

void setup() { 
  master.begin();
  motor.attach(0, master); 
  motor.setCiA402Mode(CIA402_PV_MODE);
  master.start();
  
  motor.enable(); 
} 

void loop() {
  motor.pv_SetMotionProfileType(0);
  motor.pv_SetAcceleration(5000); 
  motor.pv_SetDeceleration(5000); 
  motor.pv_Run(1000);
  while (motor.pv_IsTargetReached() == 0);
  delay(3000);
  motor.pv_SetMotionProfileType(0); 
  motor.pv_SetAcceleration(5000);
  motor.pv_SetDeceleration(5000); 
  motor.pv_Run(-1000);
  while (motor.pv_IsTargetReached() == 0); 
  delay(3000);
}

Please see the EtherCAT CiA 402 User Manual for more QEC EtherCAT instructions and API usage.

返回頂端