setDisableOperationOptionCode()

描述

Set the disable operation option code object.

Relevant Objects

  • Object 605Ch: Disable operation option code

語法

int setDisableOperationOptionCode(int16_t value);

參數

  • [in] value

The disable operation option code to be set:

描述
-32768 … -1Manufacturer Specific
0Disable drive function
1Slow down with slow down ramp and then disabling of the drive function
2 … 32767Reserved

回傳值

Return an error code. If the returned value is zero, it indicates a successful execution of this function.

備註

This function must be called after a successful execution of EthercatMaster::begin(). This function is blocking and cannot be called in callback functions.

範例程式碼

#include "Ethercat.h"

EthercatMaster master; 
EthercatDevice_CiA402 motor;

void setup() {
  master.begin();
  motor.attach(0, master); 
  motor.setDisableOperationOptionCode(1); 
} 

void loop() { 
  // put your main code here, to run repeatedly: 

}
返回頂端