[EthercatDevice_DmpHID_Generic]
Description
Read the Enable switch value of the MPG for the EtherCAT slave device.
Derived Class:
Class Name | Vendor ID | Product Code | UART | Keypad | LCM | MPG |
EthercatDevice_QECR11HU1S | 0x00000bc3 | 0x0086d404 | O | O | ||
EthercatDevice_QECR11HU9S | 0x00000bc3 | 0x0086d402 | O | O | O | O |
EthercatDevice_QECR00HU9S | 0x00000bc3 | 0x0086d401 | O | O | O | O |
Syntax
int mpgReadEnableSwitch();
Parameters
None.
Return Value
Return the Enable switch value, 1 means the enable switch signal pulls HIGH, and 0 means LOW. If the return value is smaller than 0, it means an error code.
Comment
This function must be called after a successful execution of EthercatMaster::start()
and before EthercatMaster::stop()
. This function is non-blocking and can be called within the callback functions.
Example
#include "Ethercat.h" EthercatMaster master; EthercatDevice_QECR11HU9S slave; void CyclicCallback() { slave.update(); } void setup() { Serial.begin(115200); master.begin(); slave.attach(0, master); master.attachCyclicCallback(CyclicCallback); master.start(); } void loop() { Serial.print("Enable: "); Serial.println(slave.mpgReadEnableSwitch()); delay(1000); // ... }
Please see EthercatDevice_DmpHID_Generic Class for more QEC HID slave instructions and API usage.