[Modbus]
描述
Send a packet command to the Slave node to read the Input Registers register.
語法
node1.readInputRegisters(read_address, read_size)
參數
node1
: ModbusMasterNode Object.read_address
: The starting address of the Input Registers register to be read.read_size
: The size of the Input Registers register to be read.
回傳
Int: If it succeeds, send back MODBUS_SUCCESS and vice versa, send back EXCEPTION_CODE.
範例
#include <Modbus86.h> ModbusMaster bus1; ModbusMasterNode node1; uint8_t result; uint32_t receiveData; void setup() { while(!Serial); Serial1.begin(115200); bus1.begin(MODBUS_RTU, Serial1); node1.attach(16, bus1); result = node1.readInputRegisters(5, 2); if (result != MODBUS_SUCCESS) { Serial.print("readInputRegisters => ErrorCode: "); Serial.println(result); } else { Serial.print("From Input Register receiveData: "); receiveData = node1.getResponseBuffer(0) | (node1.getResponseBuffer(1) << 16); Serial.println(receiveData); } } void loop() {}